HomeStore

CD314 (NKG2D) Monoclonal Antibody (CX5), PerCP-eFluor 710, eBioscience

CD314 (NKG2D) Monoclonal Antibody (CX5), PerCP-eFluor 710, eBioscience

PRODUCT DETAILS

Host: Rat

Isotype: IgG1, kappa

Clonality: Monoclonal

Clone: CX5

Format: PerCP-eFluor 710

Reactivity: Ms

Application: Flow Cytometry

Tested Dilution: 0.5 µg/test

Concentration: 0.2 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The CX5 monoclonal antibody reacts with the mouse NKG2D, a lectin-like molecule expressed on both human and mouse NK cells. mouse NKG2D binds to retinoic acid-inducible RAE-1 alpha, beta, gamma, delta, epsilon and the minor histocompatibility molecule H60 and has the ability to costimulate multiple NK activation receptors, through the DAP12/DAP10 adaptor molecules. NKG2D is expressed by all spleen and liver NK cells, NK1.1^+ thymocytes, in vitro activated LAK cells, and a subset of splenic NKT cells.

Applications Reported: This CX5 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This CX5 antibody has been tested by flow cytometric analysis of mouse splenocytes. This can be used at less than or equal to 0.5 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

PerCP-eFluor® 710 emits at 710 nm and is excited with the blue laser (488 nm); it can be used in place of PerCP-Cyanine5.5. We recommend using a 710/50 bandpass filter, however, the 695/40 bandpass filter is an acceptable alternative. Please make sure that your instrument is capable of detecting this fluorochrome.

Fixation: Samples can be stored in IC Fixation Buffer (Product # 00-822-49) (100 µL of cell sample + 100 µL of IC Fixation Buffer) or 1-step Fix/Lyse Solution (Product # 00-5333-54) for up to 3 days in the dark at 4°C with minimal impact on brightness and FRET efficiency/compensation. Some generalizations regarding fluorophore performance after fixation can be made, but clone specific performance should be determined empirically.

Excitation: 488 nm; Emission: 710 nm; Laser: Blue Laser.

Filtration: 0.2 µm post-manufacturing filtered.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
$500.00
CD314 (NKG2D) Monoclonal Antibody (CX5), PerCP-eFluor 710, eBioscience
$500.00
Product image 1

Description

PRODUCT DETAILS

Host: Rat

Isotype: IgG1, kappa

Clonality: Monoclonal

Clone: CX5

Format: PerCP-eFluor 710

Reactivity: Ms

Application: Flow Cytometry

Tested Dilution: 0.5 µg/test

Concentration: 0.2 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The CX5 monoclonal antibody reacts with the mouse NKG2D, a lectin-like molecule expressed on both human and mouse NK cells. mouse NKG2D binds to retinoic acid-inducible RAE-1 alpha, beta, gamma, delta, epsilon and the minor histocompatibility molecule H60 and has the ability to costimulate multiple NK activation receptors, through the DAP12/DAP10 adaptor molecules. NKG2D is expressed by all spleen and liver NK cells, NK1.1^+ thymocytes, in vitro activated LAK cells, and a subset of splenic NKT cells.

Applications Reported: This CX5 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This CX5 antibody has been tested by flow cytometric analysis of mouse splenocytes. This can be used at less than or equal to 0.5 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

PerCP-eFluor® 710 emits at 710 nm and is excited with the blue laser (488 nm); it can be used in place of PerCP-Cyanine5.5. We recommend using a 710/50 bandpass filter, however, the 695/40 bandpass filter is an acceptable alternative. Please make sure that your instrument is capable of detecting this fluorochrome.

Fixation: Samples can be stored in IC Fixation Buffer (Product # 00-822-49) (100 µL of cell sample + 100 µL of IC Fixation Buffer) or 1-step Fix/Lyse Solution (Product # 00-5333-54) for up to 3 days in the dark at 4°C with minimal impact on brightness and FRET efficiency/compensation. Some generalizations regarding fluorophore performance after fixation can be made, but clone specific performance should be determined empirically.

Excitation: 488 nm; Emission: 710 nm; Laser: Blue Laser.

Filtration: 0.2 µm post-manufacturing filtered.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
CD314 (NKG2D) Monoclonal Antibody (CX5), PerCP-eFluor 710, eBioscience | Cytek Biosciences