HomeStore

PCDH1 (Protocadherin 1) Monoclonal Antibody (CSTEM31), Alexa Fluor 488, eBioscience

PCDH1 (Protocadherin 1) Monoclonal Antibody (CSTEM31), Alexa Fluor 488, eBioscience

PRODUCT DETAILS

Host: Mouse

Isotype: IgG2b, kappa

Clonality: Monoclonal

Clone: CSTEM31

Format: Alexa Fluor 488

Reactivity: Hu

Application: Flow Cytometry

Tested Dilution: 5 µL (0.5 µg)/test

Concentration: 5 μL/Test

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with BSA and 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

This monoclonal antibody CSTEM31 reacts with human Protocadherin-1, also known as PCDH1 and cadherin-like protein 1.

Applications Reported: This CSTEM31 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This CSTEM31 antibody has been pre-diluted and tested by flow cytometric analysis of human iPSCs. This may be used at 5 µL (0.5 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.

Excitation: 488 nm; Emission: 519 nm; Laser: Blue Laser

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
$131.70

Original: $439.00

-70%
PCDH1 (Protocadherin 1) Monoclonal Antibody (CSTEM31), Alexa Fluor 488, eBioscience

$439.00

$131.70
Product image 1

Description

PRODUCT DETAILS

Host: Mouse

Isotype: IgG2b, kappa

Clonality: Monoclonal

Clone: CSTEM31

Format: Alexa Fluor 488

Reactivity: Hu

Application: Flow Cytometry

Tested Dilution: 5 µL (0.5 µg)/test

Concentration: 5 μL/Test

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with BSA and 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

This monoclonal antibody CSTEM31 reacts with human Protocadherin-1, also known as PCDH1 and cadherin-like protein 1.

Applications Reported: This CSTEM31 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This CSTEM31 antibody has been pre-diluted and tested by flow cytometric analysis of human iPSCs. This may be used at 5 µL (0.5 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.

Excitation: 488 nm; Emission: 519 nm; Laser: Blue Laser

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
PCDH1 (Protocadherin 1) Monoclonal Antibody (CSTEM31), Alexa Fluor 488, eBioscience | Cytek Biosciences